Archives
- February 2018
- November 2017
- October 2017
- September 2016
- May 2016
- March 2015
- November 2014
- July 2014
- December 2013
- May 2013
- March 2013
- December 2012
- August 2012
- July 2012
- June 2012
- May 2012
- April 2012
- March 2012
- September 2011
- August 2011
- July 2011
- May 2011
- April 2011
- March 2011
- February 2011
- September 2010
- August 2010
- July 2010
- June 2010
- May 2010
- April 2010
- February 2010
- January 2010
- September 2009
- August 2009
- July 2009
- June 2009
- April 2009
- March 2009
- February 2009
- January 2009
- December 2008
- November 2008
- October 2008
- September 2008
- August 2008
- July 2008
- June 2008
- May 2008
- April 2008
-
Meta
Category Archives: IT
Enrutamiento erroneo en Virtuozzo
En muy raras ocasiones nos pasa que tenemos un VPS en un Hardware Node y se enruta el trafico hacia otro del cluster. Cuando esto pasa, muy rara vez ocurre, pero si pasa debermeos hacer revisar la tabla de rutas … Continue reading
¿Administrar un servidor físico es igual que administrar un servidor virtual?
Si, un administrador que recibe un acceso de root a un servidor virtual debe realizar las mismas tareas que un administrador que accede a uno fisico En la infraestructura Parallels BareMetal 4 existen 2 tipos de servidores virtuales, VPS e hypervisores. Los … Continue reading
Posted in VZ
Tagged PBM VPS hypervisor virtual
Comments Off on ¿Administrar un servidor físico es igual que administrar un servidor virtual?
Calibre cables electricos
Desde hace tiempo, periodicamente entramos en la polemica del calibre adecuado de los cables electrico, asi que paso a recopilar una tabla sacada de BOE 18 setiembre 2002 num.224 pagina 96, ITC-BT-19 publicado por el ministerio de ciencia y tecnologia. … Continue reading
Posted in datacenter, DIGITALPARKS
Tagged electricidad, power
Comments Off on Calibre cables electricos
Carga en la linea electrica
La norma ANSI/IEEE C57.110-1986, recomienda que los equipos de potencia que deben alimentar cargas no lineales (computadoras ), operen a no más de un 80% de su potencia nominal. Es decir, los sistemas deben calcularse para una potencia del orden … Continue reading
“/bin/sh is needed by” metele un “rpm –rebuildb”
a veces al actualizar paquetes protesta y todo esta en orden ¿que es? regenera la BBDD de los rpm [root@hn15 CU-2.6.18-028stab068.3]# rpm -ivh *.rpm error: Failed dependencies: /bin/sh is needed by vzkernel-2.6.18-028stab068.3.x86_64 /bin/sh is needed by … Continue reading
Posted in linux, VZ
Tagged linux, rpm yum virtuozzo vz
Comments Off on “/bin/sh is needed by” metele un “rpm –rebuildb”
Sustituir un disco en un entorno RAID linux
Un pequeño apunte sobre los pasos a sguir para sustituir un disco que falla en un sistema linux, yo suelo usar centos, pero es valido para cualquier distri, cuando usamos RAID y el swap sin RAID. Los pasos son desacivar el … Continue reading
yum update python fails
Ultimamente me encuentro que a menudo me estan fallando “yum update” por el tema python, una cosa extraña. finalmente he buscado un camino simple para resolverlo y este es el camino: # yum clean all # yum –disablerepo=* –enablerepo=base –enablerepo=updates … Continue reading
Clientes remotos de SiteBuilder
Por defecto el sitebuilder en una máquina se instala y configura en: sitebuilder.nombredelamaquina.tld Si se quiere cambiar hay que hacer lo siguiente, cambiando lo que se quiere de la parte de sitebuilder: /usr/local/bin/sb_config –sb_hostname sitebuilder.domain.tld –force_update_wscfg Para cambiar la máquina … Continue reading
Cuando webmail da error user/pass
Comprobar en /var/log/psa-horde/psa-horde.log el error. Si es: Aug 05 11:22:22 HORDE [error] [imp] FAILED LOGIN 84.77.246.221 to localhost:143[imap/notls] as disvir@teatres.org [on line 258 of “/usr/share/psa-horde/imp/lib/Auth/imp.php”] Ir a /etc/hosts y añadir, sino está: 127.0.0.1 localhost localhost.localdomain Info aportada por … Continue reading
DNS falla por /dev/random
-bash-3.2# /etc/init.d/named start Starting named: named: could not open pre-chroot entropy source /dev/random: file not found [ OK ] la solución: mknod -m 0444 /dev/random c 1 8